SY-O001 Hospital Equipment Blood Dialysis Device for hemodialysis treatment Kidney Hemodialysis Machine
Product Description
Clinical Application:
> Hemodialysis (HD)
> Pure Ultrafiltration (ISO UF)
> Hemoperfusion (HP)
> Hemofiltration (HF)
> Plasma Exchange (PE)
Product Features:
· LCD touch screen with high definition(10.4").
"· Automation: Self-test, rinse, disinfection, hot disinfection, ISO UF, shutdown, etc.
Automatically start treatment once blood flow sensed."
· Bicarbonate dry powder cartridge.
· Use with dialysis fluid of various formulas (acetate & bicarbonate).
· Kt/V function.
"· Double pumps: blood pump and spare pump providing more treatment options;
Compatible with blood lines of different diameters."
· Single & Double needle dialysis.
· Using magnetic valves made in Switzerland.
· In-built battery backup for max. 30 minutes.
· Dialyzate flux linearity adjustable (300~800mL/min).
· Support bedside treatment.
· HCO3 adjustment for serious acid toxicosis patient.
Safety Guaranteed:
Audible & visible alarm with warning messages & troubleshooting.
· Blood flow monitoring.
· Arterial and Venous pressure monitoring.
· Transmembrane pressure(TMP) monitoring.
· Non invasive blood pressure(NIBP) monitoring.
"· Air Monitoring:
Air bubble detector using infrared sensor; Blood level detector using ultrasonic sensor."
· Blood leak monitoring.
· Water way entirely aparts from electric way.
· Dialyzate temperature is selectable between 35 and 39 ºC.
· Conductivity is controllable.
· Sodium and ultrafiltration profiles for various treatment conditions.
· Heparin pump timing for safety and convenience.
"· Disinfection: Rinsing, hot disinfection, chemical disinfection;
Double-circulation disinfection system:
Fluid supply loop and return loop are completely separated during disinfection to avoid
pollution of the whole machine in case of mis-sucking disinfection liquid. This gives
protection from intercross infection."
Technical Parameters:
General Data
· Dimensions: 370x340x1420mm (LxWxH)
· Weight: 90 Kg
· Water inlet pressure: 0~0.6MPa
· Water inlet temperature: 5~30ºC
· Ambient temperature: 10~30ºC
· Relative Humidity ≤70%
Extracorporeal Circuit
· Arterial pressure monitoring:
Display range: -300~+300mmHg (±10mmHg)
· Venous pressure monitoring:
Display range: -50~+300mmHg (±10mmHg)
· TMP range: -100~+600mmHg (±20mmHg)
· Blood pump/ Spare pump:
" Flow range: 15~340mL/min (φ 6mm)
20~620mL/min (φ 8mm)"
· Blood level detector: ultrasonic sensor.
· Air bubble detector: infrared sensor.
" Threshold of reaction: single air bubble of 200 μI
exists when blood flux is 200mL/min"
· Heparin pump:
" Delivery range: 0.1~10mL/hr (±5%) Accuracy: 0.1mL/hr
Injector size: 10/20/30mL, 20/30/50mL (optional)"
Electrical Data
|
· Power: 1500W · Frequency: 50/60Hz
|
· Voltage: AC220V±10% (110V optional)
|
Dialysis Fluid Circuit
|
· Dialysate flow range: linearity adjustable 300~800mL/min
|
· Dialysate temperature range: Selectable 35~39ºC
|
· Dialysate conductivity range: 13~15.5mS/cm (±0.1mS/cm)
|
· UF flow range: 0~4000mL/hr (±30mL/hr)
|
· ISO UF flow range: 0~2000mL/hr (±30mL/hr)
|
·Blood leak detector:
|
Automatically close the blood loop when blood leak ≥1mL per
liter dialysate (Flow: 500mL/min)
|
Disinfection and Cleaning
|
· Disinfection: Use citric acid, peracetic acid and sodium hypochlorite.
|
· Hot rinse temperature: 90ºC
|
Detailed Photos
Company Profile